Jump to: navigation, search

GVP MCP:mpc:cpa-fastbusy



View in ref guide.

Edit this option          Publish this option          Clear draft content


Published Option

cpa.fastbusy

Default Value: na_fastbusy
Valid Values: Any combination of: "na_ringback", "na_busy", "na_fastbusy", "na_sit_nocircuit", "na_sit_vacantcircuit", "na_sit_operatorintercept", "na_sit_reorder", "standard_fax", "tone1", "tone2", "tone3", "tone4", "tone5", "tone6", "tone7", "tone8", "tone9" and "tone10". Or "none".
Changes Take Effect: At start/restart


Specifies tones for CPA's fast busy pattern. Default tone value is builtin North American fast busy (NA fast busy). Value "Disable" disables fast busy detection. Valid tones include builtins and Custom tone 1 to Custom tone 10.

The builtin North American fast busy has three segments. All segments are the same and are defined as follows:
Segment 1: f1=460-500(Hz), f2=600-640(Hz), ontime=160-320(ms), offtime=180-320(ms)
Segment 2: f1=460-500(Hz), f2=600-640(Hz), ontime=160-320(ms), offtime=180-320(ms)
Segment 3: f1=460-500(Hz), f2=600-640(Hz), ontime=160-320(ms), offtime=180-320(ms)

Draft Option

No draft option

This page was last edited on June 29, 2020, at 15:49.