Jump to: navigation, search

GVP MCP:mpc:cpa-preconnectresult-sit vacantcircuit-list



View in ref guide.

Edit this option          Publish this option          Clear draft content


Published Option

cpa.preconnectresult.sit_vacantcircuit.list

Default Value:
Valid Values: Can be an empty string or a space separated list of numbers ranging from 0 to 100.
Changes Take Effect: Immediately/session


Specifies list of carrier message files associated with result sit_vacantcircuit in preconnect mode. The list is a sequence of integer number equal to the index of carrier message previously specified. Example: cpa.preconnectresult.sit_vacantcircuit.list = 0 2 4 It means that if incoming message matches with carriermsg.0, carriermsg.2 or carriermsg.4 then CPA outputs result = sit.vacantcircuit.