View in ref guide.
Edit this option Publish this option Clear draft content
Published Option
timer.ci_proceeding
Default Value: 120000
Valid Values: sip.timer.ci_proceeding must be an integer that is greater than 0 and less than or equal to the maximum integer as defined by the Genesys Administrator Help.
Changes Take Effect: At start/restart
Defines the client INVITE proceeding timer in milliseconds, default value is 120000.
The timer starts after a 1xx response is received for a client INVITE. If a final
response is not received before the timer expires, the SIP session and dialog will be
destroyed without further notice to the UAS. Note that the CI proceeding timer should
be configured to be greater than the connect timeout of the outbound call (depending on
how the outbound call is initiated, the connect timeout can be specified in the transfer
tag, or in the remdial command). Otherwise, the Client Invite Proceeding Timer will be
triggered before the connect timeout occurs, which overrides the connect timeout as a result.
Draft Option
No draft option