LineSideSection

The line-side section is ignored when CPD Server is used with Dialogic DM3 hardware. The /config/fcd/pcd Dialogic files must be used instead.

Note: If you are using the line-side-dm3 and cas-dm3 line types, you cannot modify the bit mask parameters through the CPD Server configuration options. Instead, you use the Dialogic *.config, *.fcd, and *.pcd files. These files are located at $DIALOGICDIR\data. Consult the Dialogic documentation for more information on modifying these files.

off-hook-bit-mask

  • Type: Optional
  • Default Value: a-on;b-on;
  • Valid Value(s): a-off;b-on; a-off;b-off; a-on;b-off; a-on;b-on;
  • Specifies the mask for a T1/E1 line that is off-the-hook.

on-hook-bit-mask

  • Type: Optional
  • Default Value: a-off;b-on;
  • Valid Value(s): a-off;b-on; a-off;b-off; a-on;b-off; a-on;b-on;
  • Specifies the mask for a T1/E1 line that is on-the-hook.

rcv-idle-bit-mask

  • Type: Optional
  • Default Value: a-off;b-on;
  • Valid Value(s): a-off;b-on; a-off;b-off; a-on;b-off; a-on;b-on;
  • Specifies the mask that indicates a T1/E1 line in an idle state.

snd-idle-bit-mask

  • Type: Optional
  • Default Value: a-off;b-on;
  • Valid Value(s): a-off;b-on; a-off;b-off; a-on;b-off; a-on;b-on;
  • Specifies the mask that the Dialogic board sends to a switch to make a T1/E1 line idle.