Revision as of 19:14, July 10, 2018 by Jdruker (talk | contribs)
Jump to: navigation, search

GVP MCP:mpc:op-flushingtime









View in ref guide.

Edit this option          Publish this option          Clear draft content


Published Option

op.flushingtime

Default Value: -1
Valid Values: mpc.op.flushingtime must be an integer that is at least equal to -1 and less than or equal to 1000
Changes Take Effect: At start/restart


The packet flushing time for the Operator. Will flush data if new data does not arrive within this time period. This can be useful when deployed against a VAD (Voice Activation Device) that sends audio only when there is audio. Normally, the inband DTMF detection algorithm relies on audio being sent after a DTMF is detected to determine the end of a DTMF. For the case where audio data stops at the end of the inband DTMF, this value specifies the delay time before signalling the end of an inband DTMF.

Draft Option

No draft option