View in ref guide.
Edit this option Publish this option Clear draft content
Published Option
cpa.sit_operatorintercept
Default Value: na_sit_operatorintercept
Valid Values: Any combination of: "na_ringback", "na_busy", "na_fastbusy", "na_sit_nocircuit", "na_sit_vacantcircuit", "na_sit_operatorintercept", "na_sit_reorder", "standard_fax", "tone1", "tone2", "tone3", "tone4", "tone5", "tone6", "tone7", "tone8", "tone9" and "tone10". Or "none".
Changes Take Effect: At start/restart
Specifies tones for CPA's SIT operator intercept pattern. Default tone
value is builtin North American SIT operator intercept
(NA SIT operator intercept).
Value "Disable" disables SIT operator intercept detection. Valid tones
include builtins and Custom tone 1 to Custom tone 10.
The builtin North American sit operator intercept has three segments.
Each segment is defined as follows:
Segment 1: f1=874-955(Hz), f2=0-0(Hz), ontime=160-300(ms), offtime=0-60(ms)
Segment 2: f1=1310-1430(Hz), f2=0-0(Hz), ontime=160-300(ms), offtime=0-60(ms)
Segment 3: f1=1740-1850(Hz), f2=0-0(Hz), ontime=320-440(ms), offtime=0-100(ms)
Draft Option