Revision as of 19:25, July 10, 2018 by Jdruker (talk | contribs)
Jump to: navigation, search

GVP MCP:mpc:recordpostbacklogthreshold









View in ref guide.

Edit this option          Publish this option          Clear draft content


Published Option

recordpostbacklogthreshold

Default Value: 25
Valid Values: mpc.recordpostbacklogthreshold must be an integer that is greater than or equal to 1 and less than or equal to the maximum integer as defined by the Genesys Administrator Help.
Changes Take Effect: At start/restart


While doing MSML call recording the recordings are added to a list if they need to be posted to Amazon S3, Call Recording API, HTTP/HTTPS or SpeechMiner. A separate posting thread wakes up from time to time and works on the list of recordings to be posted. If due to any reason the posting thread lags behind, then we send an alarm notification as soon as the post backlog reaches or exceeds the threshold limit specified by this parameter. We send another alarm notification when the post backlog is below the configured threshold. The default value is 25, which means that we send an alarm when the post backlog reaches or exceeds 25 posts.

Draft Option

No draft option

Comments or questions about this documentation? Contact us for support!