Revision as of 18:52, January 14, 2019 by Jdruker (talk | contribs)
Jump to: navigation, search

GVP MCP:sip:mpc-copyheaders



View in ref guide.

Edit this option          Publish this option          Clear draft content


Published Option

mpc.copyheaders

Default Value: X-Genesys-geo-location
Valid Values: A valid header can only contain alphanumeric characters, '.', '-', ':', '/' and '\' characters, and space is used to separate the headers
Changes Take Effect: At start/restart


Copy the specified headers from inbound call INVITE messages and pass them to the MPC. These headers are currently used by the third-party call recording feature only, and are copied to the out-going INVITE messages to a recorder. If "none" is the only value present, no headers will be copied. Empty string results in the default value being used. Note that the special value "*" is not supported for this parameter.

Draft Option

No draft option