Default Value: -1
Valid Values: mpc.op.flushingtime must be an integer that is at least equal to -1 and less than or equal to 1000
Changes Take Effect: At start/restart
The packet flushing time for the Operator. Will flush data if new data does not arrive within this time period.
This can be useful when deployed against a VAD (Voice Activation Device) that sends audio only when there is audio.
Normally, the inband DTMF detection algorithm relies on audio being sent after a DTMF is detected to determine the end of a
DTMF. For the case where audio data stops at the end of the inband DTMF, this value specifies the delay time before signalling
the end of an inband DTMF.