GVP MCP:mpc:cpa-busy
View in ref guide.
Edit this option Publish this option Clear draft content
Published Option
Draft Option
No draft option
Comments or questions about this documentation? Contact us for support!
View in ref guide.
Edit this option Publish this option Clear draft content
Published Option
Default Value: na_busy
Valid Values: Any combination of: "na_ringback", "na_busy", "na_fastbusy", "na_sit_nocircuit", "na_sit_vacantcircuit", "na_sit_operatorintercept", "na_sit_reorder", "standard_fax", "tone1", "tone2", "tone3", "tone4", "tone5", "tone6", "tone7", "tone8", "tone9" and "tone10". Or "none".
Changes Take Effect: At start/restart
Specifies tones for CPA's busy pattern. Default tone value
is builtin North American busy (NA busy). Value "Disable"
disables busy detection. Valid tones include builtins and Custom tone 1
to Custom tone 10.
The builtin North American busy has three segments. All segments
are the same and are defined as follows:
Segment 1: f1=460-500(Hz), f2=600-640(Hz), ontime=360-640(ms), offtime=360-640(ms)
Segment 2: f1=460-500(Hz), f2=600-640(Hz), ontime=360-640(ms), offtime=360-640(ms)
Segment 3: f1=460-500(Hz), f2=600-640(Hz), ontime=360-640(ms), offtime=360-640(ms)
Draft Option
No draft option