Revision as of 17:40, February 20, 2020 by Vivian (talk | contribs) (Vivian used the OptionEdit action.)
Jump to: navigation, search

DataLoader:dataset-zname-:chunk-size


View in ref guide.

Edit this option          Publish this option          Clear draft content


Published Option

chunk-size

Default Value: PT15M (15 minutes)
Valid Values: String in ISO 8601 duration format, PT1S (1 second) or higher
Changes Take Effect: Immediately


Defines the chunk size, defined as interactions that happened within the specified length of time, used when extracting data from the Genesys Info Mart Database for a dataset of the interactions data type. Interactions that started within the chunk, as defined by this option value, are uploaded to the GPR Core Services platform as a single file and are then appended to the previously uploaded data for the associated dataset.

The following table provides sample formats that are supported for the chunk-size option.

Value Description
PT20.345S Specifies 20.345 seconds
PT15M Specifies 15 minutes
PT10H Specifies 10 hours
P2D Specifies 2 days
P2DT3H4M Specifies 2 days, 3 hours and 4 minutes
P-6H3M Specifies -6 hours and +3 minutes
-P6H3M Specifies -6 hours and -3 minutes
-P-6H+3M Specifies +6 hours and -3 minutes