Contents
Configuring the Options Tab for QIL
In Configuration Manager, configuration options are stored within section folders. The section folders and options are stored on the Options tab; you click a section to bring up its options. Options are described in detail below.
general Section
agent-place
- Default Value: ““
- Valid Values: A string representing an existing system Place (a Place that is not used by an Agent ).
- Changes Take Effect: After restart.
- Description: Used to connect to Interaction Server, to make it possible to perform ad-hoc features.
log Section
omsdk-console
- Default Value: info
- Valid Values: false, debug, info, warn, error, fatal
- Changes Take Effect: After restart.
- Description:
Level and size of traces to display on the standard output.
Non-mandatory.
omsdk-file
- Default Value: info, omsdk.log, 10, 20
- Valid Values: <level>, <filename>, <max filesize>, <max filenumber>
-
<level>: false, debug, info, warn, error, fatal
-
<file name>: correct path to a file name
-
<max file size>
- maximum file size in MB
- maximum file size in MB
-
<max file number>: number of files for the rolling logs
- Changes Take Effect: After restart.
- Description:
Used to put OMSDK trace messages in the file. If this option is not specified, OMSDK logging to the file is not used.
Non-mandatory.
omsdk-msgsrv
- Default Value: off
- Valid Values: off, debug, info, warn, error, fatal
- Changes Take Effect: After restart.
- Description:
Specifies the level and size of OMSDK to display in the MessageServer centralized log. If this option is not specified, OMSDK logging to MessagerServer is not used.
Non-mandatory.
log-filter Section
For Filtering Sensitive Data to Logs
default-filter-type
- Default Value: copy
- Valid Values: copy, hide, skip
- Changes Take Effect: After restart.
- Description:
Specifies the default way of logging key/value information:
- copy—copy each pair’s key and value to the log.
- hide—copy keys to the log, but replace values with strings of asterisks.
- skip—do not copy key/value pairs to the log.
log-filter-data Section
For Filtering Sensitive Data to Logs
<key-name>
- Default Value: copy
- Valid Values: copy, hide, skip
- Changes Take Effect: After restart.
- Description: Specifies how to log key/value pairs for the specified <key-name> key:
- copy—copy key/value pairs to the log.
- hide—copy the key to the log, but replace values with strings of asterisks.
- skip—do not copy key/value pairs to the log for the specified key.
settings Section
enable-attached-data-byte-array
- Default Value: true
- Valid Values: true, false
- Changes Take Effect: After restart.
- Description:
This option specifies the conversion method for binary data in ESP requests and responses.
- If set to true, QIL converts binary data from a request to an array of bytes (byte[]) and expects that in responses, binary data will be of the same type.
- If set to false, QIL converts binary data to an ArrayList of objects with class Byte. Same for responses.
workflow Section
request-timeout
- Default Value: 5000
- Valid Values: <Any positive integer>
- Changes Take Effect: After restart.
- Description:
Used for specifying a request timeout for the Interaction Server service. If an answer is not received from IxnServer within the specified period, a corresponding TimeoutException will be thrown. Specified in milliseconds.
Non-mandatory.
This page was last edited on January 7, 2014, at 16:04.