To configure monitoring for the components that you want to monitor from within the SIP Feature Server administration web application:
- In Genesys Administrator, add the components to be monitored in the Connections tab of Feature Server applications.
- Using the following table, create an http-port ID in the applications of the components that are to be monitored, where <port> is any free port in the host machine of a specific component:
Application | Navigate to | Value |
---|---|---|
SIP Server | Options > TServer | <port> |
Stat Server | Server Info | <port> |
ICON | Server Info | <port> |
URS | Server Info | <port> |
SIP Proxy | Server Info | <port> |