How to Configure Alarm Conditions and Alarm Reactions
Although you can configure Alarm Condition objects and Alarm Reaction scripts manually, using Genesys Administrator, the Management Layer provides an automated procedure.
You can configure new Alarm Conditions based on either source for their detection:
Log Events—These Alarm Conditions trigger an alarm when an application or applications generate a specified log event.
Alarm Detection Scripts—These Alarm Conditions trigger an alarm when a certain system variable changes in a specified manner.
For alarms based on log events, alarm detection takes place in Message Server. Therefore, if you configure log event–based Alarm Conditions, you must configure your applications to connect to Message Server.
Using Log Events for Alarm Detection
To configure alarm conditions or alarm reactions in Genesys Administrator, create the alarm condition or alarm reaction under Provisioning > Environment > Alarm Conditions, being sure to specify the appropriate log event on the Configuration tab. You can also use pre-configured Alarm Condition objects. Refer to Genesys Administrator Help for detailed instructions about creating and using these necessary objects.
You can also use the Alarm Condition Wizard to associate Alarm Reactions with the Alarm Condition you are configuring.
For complete specifications of log events reported at the Alarm, Interaction, Standard, and Trace levels, see Framework Combined Log Events Help.
Using Detection Scripts for Alarm Detection
Management Layer provides an additional alarm-detection mechanism, called Advanced Alarm Detection. Through this mechanism, you can configure Alarm Conditions:
Based on the threshold for a system performance variable (CPU or memory usage).
Based on the threshold for a local or remote SNMP variable (available only when you have enabled SNMP functionality).
Set alarms based on the Advanced Alarm Detection methods using Alarm Detection scripts, and then associate them with corresponding Alarm Conditions. When an Alarm Condition object refers to an Alarm Detection script, the alarm detection for this Alarm Condition is performed as specified by the Alarm Detection script, regardless of whether any log event is specified as a Detection Event.
Using Alarm Detection and Reaction Scripts with Alarm Conditions
To configure an Alarm Detection Script, do the following:
Navigate to the folder in which you want to store the new script, and click New.
Enter the following information for the new script:
Enter the Name of the script.
Make sure that State Enabled is checked.
From the Script Type drop-down list, select Alarm Detection.
From the Detection Types drop-down list, select one of the following tabs and proceed accordingly. Note that you must have SNMP functionality in your environment to monitor SNMP variables.
To monitor a performance variable for a given Host, provide the following information:
Enter the DNS or IP address of the Host to be monitored.
From the Select Monitored Resource drop-down list, select the resource to be monitored, either Host CPU Usage (%) or Host Memory Usage (MB).
To monitor a performance variable for a given Application, provide the following information:
Select the Application to be monitored.
From the Select Monitored Resource drop-down list, select the resource to be monitored, either Process CPU Usage (%) or Process Memory Usage (MB).
Important
You must have SNMP functionality configured in your environment to monitor SNMP variables.
To monitor a local SNMP variable, enter the oid of the variable in Specify Local SNMP Variable.
Important
You must have SNMP functionality configured in your environment to monitor SNMP variables.
To monitor a remote SNMP variable, provide the following information:
Select the SNMP Agent Application in which the variable is used.
Enter the name of the variable to be monitored in Specify Local SNMP Variable.
In Specify Sample Interval, specify (in seconds) the frequency with which to take a sample of the required information.
In Specify Falling Threshold, specify the level at which the monitored attribute must fall below to clear the alarm. Your entry must be in the same units of measure as the units of measure specified for the resource or variable that you are monitoring.
In Specify Rising Threshold, specify the level at which the monitored attribute must rise above to trigger the alarm. Your entry must be in the same units of measure as the units of measure specified for the resource or variable that you are monitoring.
Click Save.
If there is a specific automated action that you want to happen as a result of the alarm, configure an Alarm Reaction script. For example, to generate an SNMP trap when this alarm is triggered, do the following:
Navigate to the folder in which you want to store the new script, and click New.
Enter the following information for the new script:
Enter the Name of the script.
Make sure that State Enabled is checked.
From the Script Type drop-down list, select Alarm Reaction.
From the Alarm Reaction Types drop-down list, select Send an SNMP trap. You must have SNMP functionality in your environment to monitor SNMP variables.
Click Save.
To create the corresponding Alarm Condition object, follow these steps:
Navigate to the folder in which you want to store the new Alarm Condition, and click New.
On the General tab, enter the following information for the new script:
Enter the Name of the Alarm Condition.
(Optional) Provide a short Description of the Alarm Condition.
From the Category drop-down list, select the severity of the Alarm Condition, either Critical, Major, or Minor.
In the Detect Script field, specify the name of the Alarm Detection Script that you created above, using the provided browser control if necessary.
In the Cancel Timeout field, specify the time interval (in seconds) after which the alarm will be cleared by SCS. If the host CPU is still not normalized, the alarm will be generated again.
In the Detect Log Event ID and Cancel Log Event ID fields, enter any numeric dummy value. These two fields are not used if you are using an Alarm Detection Script, and while ignored by the Management Layer in this case, are still mandatory.
From the Detect Selection drop-down list, select the mode for event selection that the Management Layer uses for Alarm Condition analysis. Refer to Alarm Conditions in GAX Help for a detailed description of this field.
Make sure that State Enabled is checked.
If you have created an Alarm Reaction Script for this Alarm Condition, link the Reaction Script to this Alarm Condition, as follows:
If you have created an Alarm Clearance Script for this Alarm Condition, link the Clearance Script to this Alarm Condition. In this case, an Alarm Reaction of type "Send an SNMP trap" also acts as its own Alarm Clearance Script, since there is no waiting involved; that is, once the Alarm Reaction is complete, the Alarm can be cleared—the trap has been sent. So, you just need to specify the same script as the Clearance Script, as follows:
You can configure alarm reactions of the following types:
Start a specified application
Stop a specified application
Restart the application that generated the alarm
Start a specified solution
Send an email
Send an SNMP trap
Switch over to the backup application
Execute OS command
Change application option
The configuration procedure for most of the alarm reactions is self-explanatory in the Alarm Reaction Wizard. You must supply information for these configuration parameters:
A unique name for the Alarm Reaction configuration object (for all types of alarm reactions).
A name of the application or solution the alarm reaction is configured for (for alarm reactions of such types as Start a specified application, Stop a specified application, Start a specified solution, and Restart the application that generated the alarm).
You must provide additional information for alarm reactions of the following types:
You must have a high-availability (HA) license to enable Solution Control Server to successfully process an alarm reaction of the Switchover type. The lack of the license prevents the switchover between primary and backup applications of any type.
When configuring an alarm reaction of the Switchover type, you can specify whether Solution Control Server should perform the switchover when an application, which generates an alarm, is running in a particular mode:
Select primary if you want SCS to perform a switchover only if the application that has generated an alarm is currently operating in Primary mode.
Select backup if you want SCS to perform a switchover only if the application that has generated an alarm is currently operating in Backup mode.
Select perform switchover always if you want SCS to perform a switchover regardless of the operating mode of the application that generates the alarm.
You might use these options, for instance, when associating an alarm reaction of the Switchover type for T-Server with the CTI Link Disconnected log event. Selecting primary for the alarm reaction configuration may prevent an
unwanted switchover if the T-Server that produced this log event currently operates in Backup mode.
Send an E-Mail
To configure an alarm reaction of type Send an E-Mail, specify the recipients of the email in the Alarm Reaction Wizard. Then, compose the subject and text of the email message, using reserved variables. See Genesys Administrator Help for detailed instructions on configuring the email script, including an example. See E-Mail Alarm Reactions for more information about the email interface itself.
Send an SNMP Trap
To configure an alarm reaction of the Send an SNMP Trap type, specify a Name for the Alarm Reaction configuration object. All necessary information is automatically provided by SCS, given that the SNMP Master Agent application is configured correctly.
See SNMP Interface for more information about enabling the SNMP alarm signaling.
Execute OS command
To configure an Alarm Reaction of the Execute OS Command type, specify the name of the operating system command that is to be executed when an alarm is detected. If necessary, include the full path to the executed command.
Important
Although you can specify any valid command name, use alarm reactions of this type with caution. To avoid unauthorized actions, limit access to Solution Control Server and Genesys Administrator to the Administrators group.
SCS executes all alarm reactions. In the case of an alarm reaction of the Execute OS Command type, SCS executes the specified command on its own host computer. Therefore, a currently logged in user must have sufficient
permissions to execute the specified operating system command.
SCS passes information about a detected alarm to the operating system command to be executed. For this purpose, SCS adds command-line arguments (listed in the table below) to the command line you specify in the Command property when you configure the alarm reaction.
Important
Some applications started as a result of the Execute OS Command alarm reaction may not recognize the command-line arguments added by SCS. This means that these applications might not work properly in this circumstance; for example, they might exit. To make them work, you can call such applications indirectly; for instance, from within a script that passes correct command-line parameters to these applications. You then specify name of this script in the Command property of the alarm reaction.
Additional Command-Line Parameters
The following table describes the additional command-line parameters that are added to the Command property when you configure an Execute OS Command Alarm Reaction.
Additional Command-Line Parameters for Execute OS Command Alarm Reactions
-msgid
ID of the log event that resulted in the alarm
-msgtext
Text of the log event that resulted in the alarm
-condid
Alarm Condition ID
-condname
Alarm Condition Name
-conddesc
Alarm Condition Description
-appid
ID of the application that generated the log event that resulted in the alarm
-appname
Name of the application that generated the log event that resulted in the alarm
-hostname
Name of the application host that generated the log event that resulted in the alarm
Examples
The following are examples of how to use and configure Execute OS Command Alarm Reactions. [+] Show examples
Example 1 - Filtering by type of log event
To log occurrences of certain log events to a database other than the Genesys Log Database, create a *.bat file that provides logging in to your independent database. Name this file process_alarm.bat. Then using the Alarm Reaction Wizard, configure an Alarm Reaction of the Execute OS Command type and set the Command property to:
/home/Genesys/SCServer/scripts/process_alarm.bat
When a corresponding alarm is detected, SCS executes the following operating system command:
/home/Genesys/SCServer/scripts/process_alarm.bat -msgid 20002 -msgtext "CTI Link disconnected" -condid 103 -condname "CTI Link Failure" -conddesc "Failure of connection between any T-Server and a switch." -appid 120 -appname "T-Server_Application" -hostname “NameOfHost”
Important
If a specified operating system command normally would result in a screen display, the alarm reaction is performed, but the screen output cannot be enabled and, therefore, cannot be seen.
Example 2 - Collecting information about alarms
A script called react_script.sh, for the bash UNIX shell, saves information about each alarm in the reaction.log text file located in the /home/genesys/logs/ directory:
Example 3 - Filtering by the host that generated the alarm
To save information about alarms generated by a specific host, you must create a script that writes only those logs generated by a specific host. The following sample script, HostA_alarms.sh for the bash UNIX shell, writes only those alarms generated by HostA to the HostA_reactions.log text file located in the /home/genesys/logs/ directory.
while [ 0 -lt "$#" ]; do case "$1" in "-msgid") shift; MSGID="$1" ;; "-msgtext") shift; MSGTEXT="$1" ;; "-condid") shift; CONDID="$1" ;; "-condname") shift; CONDNAME="$1" ;; "-conddesc") shift; CONDDESC="$1" ;; "-appid") shift; APPID="$1" ;; "-appname")shift; APPNAME="$1" ;; "-hostname")shift; HOSTNAME="$1" ;; esac shift done if [ $HOSTNAME = "HostA" ]; then echo `date|cut -c4-16` : msgid=$MSGID : msgtext=$MSGTEXT : condid=$CONDID : condname=$CONDNAME : conddesc=$CONDDESC : appid=$APPID : appname=$APPNAME >> HostA_reactions.log fi
Change application option
Management Layer allows execution of Alarm Reactions not only at Alarm activation, but also at Alarm clearance. To achieve this, add the Alarm Reactions that are to be executed when the Alarm is cleared to the Clearance Scripts list of the corresponding Alarm Condition object. You can also use the Alarm Condition Wizard to accomplish this.