9.0.120.35
Genesys Intelligent Automation Release Notes
Release Date | Release Type | Restrictions | AIX | Linux | Mac | Solaris | Windows |
---|---|---|---|---|---|---|---|
08/10/23 | Hot Fix | X |
Helpful Links
Releases Info
Product Documentation
Genesys Products
What's New
This release includes only resolved issues.
Resolved Issues
This release contains the following resolved issues:
This release addresses a critical issue that was identified in the earlier 9.0.120.32 release. This release is specific to the Oracle database migration that have been corrected. (SPCHSTRM-4115)
The hive-off process has been updated for improved performance for the Oracle database:
- The days-tables are partitioned vertically, day sized.
- Keys used for partitioning are indexed.
- Additional indexes (CALL_STEPS_IDX1, DAILY_HEALTH_AGGREGATES_IDX1, DAILY_DASHBOARD_AGGREGATES_IDX1, DAILY_DASHBOARD_AGGREGATES_IDX2, and DAILY_HEALTH_AGGREGATES_START_IDX1) are added for performance.
- Hive-off will now not copy from day-tables to historical-tables.
- Old historical data will be deleted from the day tables, instead of from the historical tables. This helps in dropping partitions quickly improving performance.
(SPCHSTRM-3907, SPCHSTRM-4021, SPCHSTRM-4022)
Upgrade Notes
No special procedure is required to upgrade to release 9.0.120.35.