Options in this section define the connection between Genesys SNMP Master Agent and Solution Control Server (SCS).
This section must be called agentx.
Default Value: 0
Valid Values: 0—2
Changes Take Effect: After restart
Specifies the host network for connection between SCS and Genesys SNMP Master Agent. The following are the valid values:
Default Value: TCP
Valid Values: TCP
Changes Take Effect: After restart
Specifies the connectivity mode for the AgentX-protocol connection between Genesys SNMP Master Agent and SCS. If you do not configure the option, don’t set its value, or set it to TCP, Genesys SNMP Master Agent uses a TCP/IP socket for the connection. The tcp_port configuration option defines the actual port number in this case.
Default Value: 705
Valid Values: Any valid port number
Changes Take Effect: After restart
Specifies the port number Genesys SNMP Master Agent opens for connection in TCP mode. When you do not configure the option, don’t set its value, or set it an invalid (non-integer or zero) value, Genesys SNMP Master Agent opens the default port (705) for the TCP/IP connection.