This release includes only resolved issues.
Resolved Issues
This release contains the following resolved issues:
In SCS audit logs, for any Application of type CFGSCI with a username of NULL, the username in the log is now displayed as GAX_Backend or as the value of the default-audit-username option set in the [general] section of the SCS Application object. Previously in this scenario, when starting Genesys Administrator Extension, SCS generated the message ERROR: Cannot find request for request ID: 28 ignoring CFGBriefInfo event.
[general]
default-audit-username
Default value: GAX_backend
Valid Values: Name of any configured Application
Changes Take Effect: After restart
Specifies the default login username for GAX, because there is no provided username when connecting to SCS.
(MFWK-17455)
SCS now checks for a NULL condition in the g_pSnmpThread object before it invokes a timer callback. Previously, SCS did not do a NULL check, generated a core file and terminated unexpectedly. (MFWK-17410)
SCS now clears an existing restart alarm before setting a new alarm. Previously in this scenario, the existing alarm was deemed to be expired and the application restarted. (MFWK-16876)