Contents
Workbench Agent Application Type
General Section
Editable Options
Workbench Application Name
Default Values: "WBA_<HOSTNAME>"
Valid Values: Any String (i.e. "WBA_MY-VM")
Changes Take Effect: Immediately
Description: The name of the Workbench Agent application
Workbench Agent Port
Default Values: 9091 (or the port number given at custom installation time)
Valid Values: A valid and free Port number (i.e. not used by other applications on the host)
Changes Take Effect: After Workbench Agent application (i.e. "WB_Agent_Primary") restart
Description: The Port at which clients connect
Read Only Options
Workbench Application Type
Default Values: "Workbench Agent"
Valid Values: Valid Workbench Application Type
Changes Take Effect: N/A
Description: Workbench Application Type
Workbench Version
Default Values: "9.x.xxx.xx"
Valid Values: WB Version
Changes Take Effect: After Workbench Agent application (i.e. "WB_Agent_Primary") startup
Description: The Workbench Application Version
Data-Center
Default Values: default
Valid Values: Read-Only
Changes Take Effect: Aftern Workbench Agent application (i.e. "WB_Agent_Primary") startup
Description: The name of the Data-Centre associated with this application; a prepatory setting that will evolve in WB 9.x
Host Name
Default Values: Hostname of the Workbench Agent application associated host (i.e. "LAB-WB-VM1")
Valid Values: Valid Hostname
Changes Take Effect: After Workbench Agent application (i.e. "WB_Agent_Primary") startup
Description: The Hostname of the host where this Workbench Agent application is running
Host IP Address
Default Values: IP Address of the Workbench Agent application associated host (i.e. "10.20.30.40")
Valid Values: Valid IP address
Changes Take Effect: After Workbench Agent application (i.e. "WB_Agent_Primary") startup
Description: The IPv4 Address of the host where this Workbench Agent application is running
Host Time-Zone
Default Values: Time-Zone of the Workbench Agent application associated host (i.e. "Europe/London")
Valid Values: Valid Host Time-Zone
Changes Take Effect: After Workbench Agent application (i.e. "WB_Agent_Primary") startup
Description: The Time-Zone of the host where this Workbench Agent application is running
Deployment Section
Read Only Options
Installation Directory
Default Values: "<WORKBENCH_HOME>\WorkbenchAgent"
Valid Values: Valid Path (i.e. C:\Program Files\Workbench_9.x.xxx.xx\WorkbenchAgent")
Changes Take Effect: After Workbench Agent application (i.e. "WB_Agent_Primary") startup
Description: Absolute path of the folder where this application is installed
Configuration Directory
Default Values: "<WORKBENCH_HOME>\WorkbenchAgent"
Valid Values: Valid Path (i.e. C:\Program Files\Workbench_9.x.xxx.xx\WorkbenchAgent")
Changes Take Effect: After Workbench Agent application (i.e. "WB_Agent_Primary") startup
Description: Absolute path of the folder where the configuration file of this application is located
Logging Section
Editable Options
Log Level
Default Values: INFO
Valid Values: ALL, INFO, DEBUG, ERROR, WARNING, FATAL, TRACE, OFF
Changes Take Effect: After Workbench Agent application (i.e. "WB_Agent_Primary") restart
Description: Application/Component Logging Level (e.g. INFO or DEBUG)
Log File Location
Default Values: "<WORKBENCH_HOME>\WorkbenchAgent\logs"
Valid Values: Valid Path (i.e. "C:\Program Files\Workbench_9.x.xxx.xx\WorkbenchAgent\logs")
Changes Take Effect: After Workbench Agent (i.e. "WB_Agent_Primary") restart
Description: Absolute path of the folder where the configuration file of this application is located
Segment (MB)
Default Values: 50
Valid Values: Valid positive integer
Changes Take Effect: After Workbench Agent application (i.e. "WB_Agent_Primary") restart
Description: Maximum size of the log file before it is rotated/cycled
Expire
Default Values: 10
Valid Values: Valid positive integer
Changes Take Effect: After Workbench Agent application (i.e. "WB_Agent_Primary") restart
Description: Maximum count of log files before rotated/cycled
MetricBeat General Section
Editable Options
Log File Location
Default Values: "<WORKBENCH_HOME>\WorkbenchAgent\logs"
Valid Values: Valid Path (i.e. "C:\Program Files\Workbench_9.x.xxx.xx\WorkbenchAgent\logs")
Changes Take Effect: After Workbench Agent (i.e. "WB_Agent_Primary") restart
Description: Absolute path of the folder where the configuration file of this application is located
Segment (MB)
Default Values: 50
Valid Values: Valid positive integer
Changes Take Effect: After Workbench Agent application (i.e. "WB_Agent_Primary") restart
Description: Maximum size of the log file before it is rotated/cycled
Expire
Default Values: 10
Valid Values: Valid positive integer
Changes Take Effect: After Workbench Agent application (i.e. "WB_Agent_Primary") restart
Description: Maximum count of log files before rotated/cycled
MetricBeat Output
Default Values: <Hostname>:<Port> of the destination Workbench Logstash application
Valid Values: Valid <Hostname>:<Port> combination
Changes Take Effect: After Workbench Agent application (i.e. "WBA_cc-app-demo-1") startup
Description: The Hostname of the host where this Workbench Agent application is running
MetricBeat Http Port
Default Values:
- For Workbench 9.0 to 9.2 - 5067 (or the port number given at custom installation time)
- For Workbench 9.3+ - 6067 (or the port number given at custom installation time)
Valid Values: A valid and free Port number (i.e. not used by other applications on the host)
Changes Take Effect: After Workbench Agent application (i.e. "WB_Agent_Primary") restart
Description: The MetricBeat Port
MetricBeat Host Metrics Section
Editable Options
Disk
Default Values: true/checked
Valid Values: true/false
Changes Take Effect: After Workbench Agent (i.e. "WBA_cc-app-demo-1") restart
Description: Collect and transmit [Disk] metrics from this Host
Network
Default Values: true/checked
Valid Values: true/false
Changes Take Effect: After Workbench Agent (i.e. "WBA_cc-app-demo-1") restart
Description: Collect and transmit [Network] metrics from this Host
Uptime
Default Values: true/checked
Valid Values: true/false
Changes Take Effect: After Workbench Agent (i.e. "WBA_cc-app-demo-1") restart
Description: Collect and transmit [Uptime] metrics from this Host
Host Metric Collection Frequency (seconds)
Default Values: 60 (seconds)
Valid Values: Valid positive integer
Changes Take Effect: After Workbench Agent (i.e. "WBA_cc-app-demo-1") restart
Description: The collect/transmit frequency for [Host] metrics from this Host
Read Only Options
CPU
Default Values: true/checked
Valid Values: true/false
Changes Take Effect: After Workbench Agent application (i.e. "WB_Agent_Primary") startup
Description: Transmit CPU stats to Workbench
Memory
Default Values: true/checked
Valid Values: true/false
Changes Take Effect: After Workbench Agent application (i.e. "WB_Agent_Primary") startup
Description: Transmit Memory (RAM) stats to Workbench
MetricBeat Associated Application Metrics Section
Editable Options
Top / Specific
Default Values: Top 10
Valid Values: Top or Specific
Changes Take Effect: After Workbench Agent (i.e. "WBA_cc-app-demo-1") restart
Description:
- If Top - collect and transmit the Top X (i.e. 10) [Application] metrics from this Host
- If Specific - collect and transmit certain (i.e. "sip" - based on a Regex match) [Application] metrics from this Host
Process Summary
Default Values: Enabled/True
Valid Values: Enabled/Disabled (True/False)
Changes Take Effect: After Workbench Agent (i.e. "WBA_cc-app-demo-1") restart
Description: Collects high level statistics about the running processes.
Application/Process Metric Collection Frequency (seconds)
Default Values: 60 (seconds)
Valid Values: Valid positive integer
Changes Take Effect: After Workbench Agent (i.e. "WBA_cc-app-demo-1") restart
Description: The collect/transmit frequency for [Application/Process] metrics from this Host